Index

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

·       

 

Manufacturer and model

Hydraulic

system

type

Maximum

pressure

(psi)

Maximum

flow

GPM

Pump model

All PM9302 and PM9303

All PM9304 and PM9306

HM1C

HM4C

HM1C

HM5C

AGCO Tractor

DT160

Closed (LS)

2900

29/39

1

2

2

1

DT180

Closed (LS)

2900

29/39

1

2

2

1

DT200

Closed (LS)

2900

29/39

1

2

2

1

DT225

Closed (LS)

2900

29/39

1

2

2

1

LT70

Open

3045

18

 

 

 

1

LT85

Open

3045

18

 

 

 

1

RT95

Closed (LS)

2900

28

1

2

2

1

RT115

Closed (LS)

2900

28

1

2

2

1

RT130

Closed (LS)

2900

29/39

1

2

2

1

RT145

Closed (LS)

2900

29/39

1

2

2

1

AGCO Allis

4650

Open (a)

2610

8.8

2

2

 

 

4660

Open (a)

2610

10.3

2

3

2

 

5650

Open (a)

2750

11

2

3

2

 

5660

Open (a)

2750

11

2

3

2

 

5670

Open (a)

2610

15.2

3

3

3

2

5680

Open (a)

2610

14.5

1

3

1

2

6670

Open (a)

2610

15.2

3

 

3

2

6680

Open (a)

2610

17.1

3

 

3

2

6690

Open (a)

2610

17.1

3

 

3

2

7600

Open (a)

2610

24.7

 

 

 

 

7630

Open (a)

2610

25.7

 

 

 

 

7650

Open (a)

2610

24.7

 

 

 

 

8360

Closed (LS)

2500

27

1

2

2

1

8425

Closed (LS)

2500

27

1

2

2

1

8610

Open (a)

2610

25

 

 

 

 

8630

Open (a)

2610

25

 

 

 

 

8745

Open

3045

25.8

 

 

 

 

Manufacturer and model

Hydraulic

system

type

Maximum

pressure

(psi)

Maximum

flow

GPM

Pump model

All PM9302 and PM9303

All PM9304 and PM9306

HM1C

HM4C

HM1C

HM5C

8765

Open

3045

25.8

 

 

 

 

8775

Closed (LS)

2900

27.7

1

2

2

1

8785

Closed (LS)

2900

27.7

1

2

2

1

9435

Closed (LS)

2900

27

1

2

2

1

9455

Closed (LS)

2900

27

1

2

2

1

9630

Closed

2250

24

1

2

2

1

9635

Closed

2250

22

1

2

2

1

9650

Closed

2250

24

1

2

2

1

9655

Closed

2250

22

1

2

2

1

9670

Closed

2500

23

1

2

2

1

9675

Closed

2500

22

1

2

2

1

9690

Closed

2500

23

1

2

2

1

9695

Closed

2500

22

1

2

2

1

9735

Closed (LS)

2900

29/39

1

2

2

1

9745

Closed (LS)

2900

29/39

1

2

2

1

9755

Closed (LS)

2900

29/39

1

2

2

1

9765

Closed (LS)

2900

29/39

1

2

2

1

9775

Closed (LS)

2900

29/39

1

2

2

1

9785

Closed (LS)

2900

29/39

1

2

2

1

9815

Closed

2750

22

1

2

2

1

(a) Optional auxiliary hydraulic reservoir is recommended to prevent overheating.

Allis Chalmers

160

Open

2300

6.7

 

2

 

 

170-G

Open

2000

10

2

3

2

 

170-D

Open

2000

10

2

3

2

 

175 CROP HUSTLER

Open

2000

11

2

3

2

 

175-G

Open

2400

11

2

3

2

 

175-D

Open

2400

11

2

3

2

 

180-G

Open

2000

10

2

3

2

 

180-D

Open

2000

10

2

3

2

 

185

Open

2000

10

2

3

2

 

185, After 1972

Open

2000

11

2

3

2

 

185-D

Open

2400

11

2

3

2

 

190-D

Open

2000

12.75

2

3

2

 

190-GXT

Open

2000

12.75

2

3

2

 

190-DXT

Open

2000

12.75

2

3

2

 

200-D

Open

2400

13.2

2

3

2

 

210

Open

2000

18

 

 

 

1

210, After 1972

Open

2400

18

 

 

 

1

220

Open

2000

18

 

 

 

1

220, After 1972

Open

2400

18

 

 

 

1

440

Open

2000

20

 

 

 

1

5015

Open

1990

5.4

 

3

 

 

5020

Open

1900

5.4

 

3

 

 

5030

Open

1900

5.4

 

3

 

 

Manufacturer and model

Hydraulic

system

type

Maximum

pressure

(psi)

Maximum

flow

GPM

Pump model

All PM9302 and PM9303

All PM9304 and PM9306

HM1C

HM4C

HM1C

HM5C

5040

Open

2133

5.75

 

3

 

 

5040, After 1978

Open

2133

6.23

 

3

 

 

5045

Open

2770

6.25

 

3

 

 

5050

Open

2133

6.23

 

3

 

 

5050, After 1978

Open

2133

6.47

 

3

 

 

6040

Open

2300

7

 

2

 

 

6060

Open

2300

10

2

3

2

 

6070

Open

2300

10

2

3

2

 

6080

Open

2300

10

2

3

2

 

6140

Open

2000

10

2

3

2

 

7000

Open

2400

5.88

 

3

 

 

7010-PD

Closed (LS)

2500

17

1

2

2

1

7010-PS

Closed (LS)

2500

17

1

2

2

1

7020

Closed (LS)

2500

17

1

2

2

1

7020-PS

Closed (LS)

2500

17

1

2

2

1

7030

Closed (LS)

2500

17

1

2

2

1

7040

Closed (LS)

2500

17

1

2

2

1

7040-PS

Closed (LS)

2500

17

1

2

2

1

7045

Closed (LS)

2500

17

1

2

2

1

7045-PS

Closed (LS)

2500

17

1

2

2

1

7050

Closed (LS)

2500

17

1

2

2

1

7060

Closed (LS)

2500

17

1

2

2

1

7060-PS

Closed (LS)

2500

17

1

2

2

1

7080

Closed (LS)

2500

18

1

2

2

1

7580

Closed (LS)

2500

18

1

2

2

1

8010

Closed (LS)

2500

17

1

2

2

1

8030

Closed (LS)

2500

17

1

2

2

1

8050

Closed (LS)

2500

17

1

2

2

1

8070

Closed (LS)

2500

17

1

2

2

1

8550

Closed (LS)

2500

18

1

2

2

1

4W220

Closed (LS)

2500

23

1

2

2

1

4W305

Closed (LS)

2500

21

1

2

2

1

4W306

Closed (LS)

2500

23

1

2

2

1

(a)   Optional auxiliary hydraulic reservoir is recommended to prevent overheating.

(1)    Best recommendation for high-performance applications

(2)    Recommended for standard applications

(3)    Will also work

Belarus

400 & 420

Open

2050

11.8

2

3

2

 

505 & 525

Open

2800

11.8

2

3

2

 

530 & 532

Open

2525

11.8

2

3

2

 

570 & 572

Open

2800

11.8

2

3

2

 

615

Open

2550

11.8

2

3

2

 

800, 802, 805

Open

2525

11.8

2

3

2

 

820, 822, 825, 825R

Open

2525

11.8

2

3

2

 

900,902,905

Open

2525

11.8

2

3

2

 

Manufacturer and model

Hydraulic

system

type

Maximum

pressure

(psi)

Maximum

flow

GPM

Pump model

All PM9302 and PM9303

All PM9304 and PM9306

HM1C

HM4C

HM1C

HM5C

920,922,925

Open

2525

11.8

2

3

2

 

1025

Open

2525

11.9

2

3

2

 

5011, 5011L

Open

2525

11.9

2

3

2

 

5045, 5045L

Open

2525

11.9

2

3

2

 

5111, 5145

Open

2525

10.9

2

3

2

 

6011, 6045

Open

2525

11.8

2

3

2

 

6311, 6345

Open

2525

11.8

2

3

2

 

1770

Open

2610

28.2

 

 

 

 

7010

Open

2000

17.8

1

 

 

2

7100

Open

2000

20

 

 

 

1

7100M

Open

2000

28

 

 

 

 

8011, 8011L, 8021

Open

2525

12.2

2

3

2

 

8311, 8345

Open

2525

12.2

2

3

2

 

9011, 9011L, 9021, 9045

Open

2525

11.8

2

3

2

 

9311, 9345

Open

2525

11.8

2

3

2

 

Case/David Brown

780

Open

2000

7.3

 

2

 

 

880

Open

2000

7.3

 

2

 

 

885

Open

2500 (a)

7.3

 

2

 

 

990

Open

2500 (a)

7.3

 

2

 

 

995

Open

2500 (a)

7.3

 

2

 

 

1200

Open

2000

6.9 (b)

 

2

 

 

1210

Open

2500 (a)

6.9 (b)

 

2

 

 

1212

Open

2500 (a)

6.9 (b)

 

2

 

 

1410

Open

2500

7.3 (b)

 

2

 

 

1410, After 1977

Open

2500

15.5

 

3

3

2

1412

Open

2500

7.3 (b)

 

2

 

 

3800

Open

2000

7.3

 

2

 

 

4600

Open

2000

7.3

 

2

 

 

(a) All 1972 model tractors and earlier have a maximum pressure of 2000 psi.

(b) Maximum flow capacity is 15.5 GPM on some models equipped with larger hydraulic pump. On these models,

the motor recommended is the HM5C for both the 9303C and 9304C pumps.

J. I. CASE

470

Open

1550

8.6

 

2

 

 

570

Open

1550

9.3

3

2

 

 

770

Open

1550

14-16

3

3

3

2

870

Open

1550

14-16

3

3

3

2

970

Open

1900

14-16

3

3

3

2

1070

Open

2100

14-16

3

3

3

2

1090

Open

2250

14-16

3

3

3

2

1170

Open

2250

14-16

3

3

3

2

1175

Open

2250

14-16

3

3

3

2

1190

Open

2200

7.25

 

2

 

 

1194

Open

2200

7.25

 

2

 

 

1270

Open

2200

20

 

 

 

 

Manufacturer and model

Hydraulic

system

type

Maximum

pressure

(psi)

Maximum

flow

GPM

Pump model

All PM9302 and PM9303

All PM9304 and PM9306

HM1C

HM4C

HM1C

HM5C

1270, After 1973

Open

2050

20

 

 

 

 

1290

Open

2200

7.25

 

2

 

 

1294

Open

2200

7.25

 

2

 

 

1370

Open

2200

20

 

 

 

 

1370, After 1973

Open

2050

20

 

 

 

 

1390

Open

2200

15.3

3

3

3

2

1394

Open

2200

15.3

3

3

3

2

1410

Open

2500